The 109SS is a rugged, accurate probe that measures soil or water temperature from -40° to +70°C. The 109SS consists of a thermistor encased in a sheath made from grade 316L stainless steel. The rugged stainless-steel sheath protects the thermistor, allowing you to bury or submerge the 109SS in harsh, corrosive environments. This probe also has a fast time response, and it can be easily interfaced with our data loggers.
Leia maisThe 109SS thermistor can survive temperatures up to 100°C, but the overmolded joint and cable should not be exposed to temperatures hotter than +70°C.
The sensor can be submerged to 46 m (150 ft) or 63 psi. Please note that the 109SS is not weighted. Therefore, the installer should either add a weighting system or secure the sensor to a fixed, submerged object, such as a piling.
The 109SS is suitable for shallow burial only. Placement of the sensor’s cable inside a rugged conduit may be advisable for long cable runs—especially in locations subject to digging, mowing, traffic, use of power tools, or lightning strikes.
Output | Analog |
Operating Temperature Range | -40° to +70°C |
Accuracy |
|
Maximum Submergence | 45.7 m (150 ft) or 434 kPa (63 psi) |
Temperature Measurement Range | -40° to +70°C |
Thermistor Temperature Survival Range | -50° to +100°C |
Overmolded Joint and Cable Temperature Survival Range | -50° to +70°C |
Interchangeability Error |
|
Steinhart-Hart Equation Error | ≤ 0.02°C (-40°) |
Time Constant in Air |
|
Sensor Description | Micro-BetaCHIP Probe 10K3MCD1, 0.5 mm (0.018 in.) diameter, 10 kohm at 25°C |
Cable Description | 0.56 cm (0.22 in.) diameter with Santoprene jacket |
Cable/Probe Connection | “ATUM” heat shrink, “Macromelt” overmolded joint |
Stainless-Steel Sheath Diameter | 0.16 cm (0.063 in.) |
Stainless-Steel Sheath Length | 5.84 cm (2.3 in.) |
Overmolded Joint Diameter | 1.02 cm (0.40 in.) |
Overmolded Joint Length | 4.24 cm (1.67 in.) |
Weight | 0.1 kg with 3.2 m cable (0.2 lb with 10.5 ft cable) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR3000 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) |
The instruction set for our CR200(X)-series, CR800-series, CR1000, and CR3000 dataloggers contains the Therm109 instruction for measuring the 109SS probe. Programming is more complicated for other data loggers because they must use generic measurement instructions.
The 109SS is suitable for shallow burial only. Placement of the sensor’s cable inside a rugged conduit may be advisable for long cable runs—especially in locations subject to digging, mowing, traffic, use of power tools, or lightning strikes.
The sensor can be submerged to 46 m (150 ft) or 63 psi. Please note that the 109SS is not weighted. Therefore, the installer should either add a weighting system or secure the sensor to a fixed, submerged object, such as a piling.
Number of FAQs related to 109SS-L: 4
Expandir todosRecolher todos
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.
Not every sensor has different cable termination options. The options available for a particular sensor can be checked by looking in two places in the Ordering information area of the sensor product page:
If a sensor is offered in an –ET, –ETM, –LC, –LQ, or –QD version, that option’s availability is reflected in the sensor model number. For example, the 034B is offered as the 034B-ET, 034B-ETM, 034B-LC, 034B-LQ, and 034B-QD.
All of the other cable termination options, if available, are listed on the Ordering information area of the sensor product page under “Cable Termination Options.” For example, the 034B-L Wind Set is offered with the –CWS, –PT, and –PW options, as shown in the Ordering information area of the 034B-L product page.
Note: As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.
To incorporate a sensor that is compatible with wireless sensor interfaces into a wireless network, a CWS900-series wireless sensor interface is needed, as well as an A205 CWS-to-PC interface to configure it.