CS210 Enclosure Humidity Sensor
Remote Monitor
Ensure ideal conditions in enclosures
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The CS210 enclosure humidity sensor measures relative humidity levels inside environmental enclosures. The sensor is housed inside the enclosure. A Campbell Scientific data logger measures this sensor and stores its data.

Leia mais

Benefícios e Características

  • Allows enclosure RH to be monitored remotely
  • Used to schedule desiccant replacement

imagens

Descrição Técnica

When CS210's measurements indicates that the RH level inside the enclosure is 40% or more, the desiccant should be replaced with another packet. 

By having the data logger measure the sensor, the measured values can be incorporated into the transmitted data stream of remotely located data loggers. The probe has an 11-in. (28 cm) cable length, which should be adequate to place the probe near the enclosure conduits.

Especificações

Sensor Elan HM2000 series precision bulk-polymer
Relative Humidity Measurement Range 0 to 100% (non-condensing)
RH Output Signal Range 0 to 1.0 Vdc
Accuracy ±3% RH (10 to 90% RH) (at 25°C)
Typical Long-Term Stability Better than 3% RH per year
Response Time 10 seconds for a 30% to 90% RH step change (at 25°C, 90% response)
Current Consumption < 0.5 mA
Supply Voltage 5 ± 0.25 Vdc
Settling Time 10 s
Operating Temperature Range 0° to 50°C
Cable Length 27.9 cm (11 in.)
Sensor Head Dimensions 2.5 x 1.3 x 0.8 cm (1.0 x 0.5 x 0.3 in.)
Weight 9 g (0.3 oz)

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Perguntas Frequentes Relacionadas

Number of FAQs related to CS210: 6

Expandir todosRecolher todos

  1. Yes. The sensor can be used with a multiplexer that is capable of making a single-ended voltage measurement.

  2. The CS210 does not have any user-serviceable parts, and it does not require any routine maintenance.

  3. Campbell Scientific recommends replacing the CS210 after every three to five years of continuous use. Alternatively, if the CS210 probe fails, replace the sensor at that time.

  4. Incorrect wiring, program errors, or a failed sensor might be the cause.

  5. The desiccant should be replaced when the top colored dot on the humidity indicator card (pn 28878) turns pink; the humidity indicator card is included in the enclosure supply kit that is shipped with each enclosure. If the CS210, Enclosure Humidity Sensor, is used, replace the desiccant when the measured humidity exceeds 35%.