RA100-L Remote Strobe and Siren Alarm
Audible and
Visual Alarms

For use with lightning
warning system
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The RA100 Remote Strobe and Siren Alarm provides visual and audible signals of alarm or status conditions. The red, amber, and blue strobes are SAE Class II LED beacons with a 100,000 hour rated lifetime and an average current drain of 0.26 A at 12.8 Vdc. The 125 dB ± 2 dB at 0.3 m (1 ft) siren has a current draw of 0.62 A at 12 Vdc, but is typically on 3 s out of 120 s, allowing the average current drain to be less than 0.02 A. The strobes and siren are mounted to 58 in. aluminum tubing that has a painted irridite and black powder coating for looks and durability.

Leia mais

Benefícios e Características

  • SAE Class II LED beacons with 100,000 hour rated lifetime
  • 125 dB ± 2 dB at 0.3 m (1 ft) siren
  • Low power consumption
  • Rugged construction
  • Easily powered and controlled by a Campbell Scientific data logger and the SDM-CD8S 8-Channel Solid-State DC Controller
  • Includes two stainless-steel brackets for mounting to a flat surface
  • Optional pole-mount kit allows mounting to a pole with a 1.5 to 4 in. outside diameter
  • Optional 3.3 ft extension allows mounting to a parapet wall

imagens

Descrição Técnica

While the RA100 is typically part of the LW110 Lightning Warning System or the RA110 Remote Alarm System, it can be purchased as a stand-alone item for many applications. It is easily powered and controlled by a Campbell Scientific data logger and the SDM-CD8S 8-Channel Solid-State DC Controller.

Especificações

LED Beacons

Rated Lifetime 100,000 h
Colors Red, amber, blue
Current Drain
  • 0.65 A (peak) @ 12.8 Vdc
  • 0.26 A (average) @ 12.8 Vdc
Diameter 14 cm (5.5 in.)
Height 16.3 cm (6.4 in.)

Siren

Sound Output 125 dB ± 2 dB at 0.3 m (1 ft)
Operating Temperature Range -20° to +65°C (-4° to +149°F)
Operating Voltage 4.8 to 14.4 Vdc
Current Drain
  • 0.62 A (maximum)
  • 0.02 A (average)

Pole

Material Aluminum tubing with irridite and black powder coating
Dimensions 1.5 m x 7.6 cm x 3.8 cm (4.8 ft x 3.0 in. x 1.5 in.)

LED Backplate

Material Aluminum
Dimensions 19.1 x 30.5 x 30.5 cm (7.5 x 12 x 12 in.)

Siren Backplate

Material Aluminum
Dimensions 12.7 x 12.7 x 0.5 cm (5 x 5 x 0.2 in.)

Mounting Bracket for Mounting to Flat Surface

Material 12 gage stainless steel
Dimensions 13.9 x 4.0 x 3.2 cm (5.5 x 1.6 x 1.3 in.)

Extension Pole

Material Aluminum tubing with irridite and black powder coating
Wind Load 233.4 kph (145 mph) wind gust or 180.3 kph (112 mph) steady winds with a safety factor of 1.25

Assumes 158.8 kg (350 lb) pullout strength of the customer-supplied 0.635-cm (0.25-in.) expansion bolts, the top mounting bracket installed just below the joint, and the bottom mounting bracket mounted at least 0.61 m (2 ft) below the top bracket.
Dimensions 1.15 m x 7.6 cm x 3.8 cm (3.5 ft x 3.0 in. x 1.5 in.)

Documentos Relacionados

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired) The CR9000X is compatible, but the RA100 requires the SDM-CD8S and the SCM-CD8S does not support the CR9000X's fastest communication rates. Therefore, the RA100 is not practical for most of the CR9000X's applications.

Additional Compatibility Information

While the RA100 is typically part of the LW110 Lightning Warning System or the RA110 Remote Alarm System, it can be purchased as a stand-alone item for many applications.

Synchronous Devices for Measurement (SDMs)

An SDM-CD8S 8-Channel Solid-State DC Controller is required when the RA100 is not used in an LW110 or RA110 system. To communicate with connected SDM devices, the CR3000 and CR5000 use the SDM-C1, SDM-C2, and SDM-C3 ports. The other data loggers use ports labeled C1, C2, and C3. The 21X also requires channel 1H.


Estudos de Caso

Utah: Lightning Warning at Schools
Lightning strikes are a serious concern for school officials who are responsible for protecting the......Leia mais

Artigos e Comunicados de Imprensa