Digital Adapters / SC-CPI
SC-CPI Datalogger-to-CPI Interface
Data Logger to CDM Bridge
Synchronized high-speed measurements
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The SC-CPI adds CPI bus functionality to your CR800, CR850, CR1000, and CR3000 dataloggers, which is necessary for them to connect to the CDM (Campbell Distributed Module) devices and other CPI-enabled sensors. The SC-CPI connects to the data logger using the C1, C2, and C3 ports.

The SC-CPI is not required for, or supported by, data loggers with a native CPI interface. Campbell Scientific strongly recommends that CDMs be connected to data loggers with a native CPI interface, such as the CR6.

Benefícios e Características

  • Enables a CR800, CR850 CR1000, or CR3000 to be part of a CPI/CDM network
  • Provides detailed CPI communication diagnostics
  • Supports monitoring of the serial or CPI load
  • Indicates if CPI frame errors occur
  • Provides information about each CPI module that it detects in its network

imagens

Especificações

Temperature Range
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Current Drain 50 mA (active)
Dimensions 15.94 x 7.49 x 3.18 cm (6.28 x 2.95 x 1.25 in.) including ground lug
Weight 0.188 kg (0.415 lb)

Connectors

CPI RJ45
Serial Connect to Data Logger Screw terminal
Computer Configuration via Device Configuration Utility USB

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR295X (retired)
CR3000 (retired)
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Additional Compatibility Information

Data Logger Considerations

A 5-conductor cable connects the data logger to the SC-CPI, and an Ethernet cable connects the SC-CPI to the CDM.

The data logger operating system must be version OS 26.

Perguntas Frequentes Relacionadas

Number of FAQs related to SC-CPI: 2

  1. To communicate with CDM devices using the CPI protocol, the CR3000, CR1000, CR850, and CR800 dataloggers require an SC-CPI device. Only one SC-CPI device per data logger is required. It is expected that the design of future Campbell Scientific data logger products will work with CPI-based modules directly.

  2. The communications protocol used by CDM devices is the CAN Peripheral Interface (CPI), which includes methods that are proprietary to Campbell Scientific.