AP200 CO2/H2O Atmospheric Profile System
Complete, Integrated System
Preprogrammed and low power
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The AP200 is a complete, integrated CO2 and H2O atmospheric profile system. It measures carbon dioxide (CO2) and water vapor (H2O) concentration from up to eight intakes, which are normally spaced along the height of a tower to give a vertical profile. The AP200 is often used in conjunction with an eddy-covariance system to measure the storage term and provide you with a more complete measure of the surface gas exchange.

Leia mais

Benefícios e Características

  • Fully integrated system
  • Requires only 13 W (average at 25°C and 12 Vdc)
  • Contains a Campbell Scientific CR1000X Measurement and Control Datalogger
  • Automatically performs CO2 zero and span
  • Automated temperature and pressure control
  • Data logger program included

imagens

Descrição Técnica

Measurements

Primary:

  • CO2 concentration at each intake
  • H2O concentration at each intake
  • System diagnostic word

Secondary:

  • Sample flow rate
  • Sample cell pressure
  • Sample cell temperature
  • Other control variables

Note: Contact the Micromet Group at Campbell Scientific for questions or updates regarding the data logger program.

Especificações

System Enclosure

Operating Temperature -30° to +45°C
Power Requirements
  • 10 to 16 Vdc (voltage)
  • 13 W (average power at 25°C)
    Average power varies from 12.5 W above +35°C to 22.5 W at -30°C.
  • 3.75 A (45 W) maximum power (cold startup)
Dimensions 52.1 x 44.5 x 29.7 cm (20.5 x 17.5 x 11.7 in.)
Weight
  • 15.9 kg (35 lb) for AP200 base model
  • 1 kg (2.3 lb) for LI-850
  • 272 g (10 oz) for CR1000KD
  • 154 g (5.4 oz) for CFM100/NL116

Pump Module

Pump Type Dual-head diaphragm pump with a brushless dc motor
Mounting Mounted in an insulated, temperature-controlled box inside system enclosure
Control Pumping speed is automatically controlled to maintain the pump inlet pressure at the set point
Maximum Pumping Speed 9.0 liters per minute (LPM)
Pressure Sensor Range 15.0 to 115.0 kPa
Heater 8.0 W (turns on/off at 2°C)
Warm-up Time ~50 min (from -30° to +2°C)
Fan 0.7 W (turns on at 50°C and off at 45°C)

Valve Manifold

Mounting Mounted inside system enclosure
Inlets Eight air sample inlets plus one inlet for zero, one inlet for CO2 span, and one inlet for H2O span
Connections 0.25-in Swagelok
Mass Flow Sensor 0 to 1.0 standard liters per minute (SLPM)
Heater 8.0 W (turns on/off at 5°C)
Warm-up Time ~20 min (from -30° to +4°C)
Fan 0.7 W (turns on at 45°C and off at 43°C)

Intake Assembly

Filter 1.0-in diameter, sintered stainless-steel disk filter, 10-micron pore size
Orifice Heater 2 kohm (0.07 W at 12 Vdc)
Mixing Volume 750 mL
Sample Connection 0.25 in. Swagelok
Number of Connections for Heater Cable Entry Seals 3 (1 in, 2 out)
Cable Diameter for Heater Cable Entry Seals 2.8 to 6.6 mm (0.11 to 0.26 in.)
Wire Diameter for Heater Cable Screw Terminals 26 to 12 AWG
Wire Stripping Length for Heater Cable Screw Terminals 5.0 mm (0.2 in.)
Screw Tightening Torque for Heater Cable Screw Terminals 0.4 N•m
Orifice Inside Diameter 0.178 mm (0.007 in.)
Dimensions 31 x 12.5 x 19 cm (12 x 5 x 7.5 in.)
Weight 1.4 kg (3.1 lb)

Downloads

AP200 CR1000 Program v.2.01 (31.3 KB) 12-01-2021

AP200 CR1000(X) Program.

Compatible with the LI-850.

Note: For those with the LI-840 contact Campbell Scientific for compatible code.

Visualize o Histórico de Revisões

Device Configuration Utility v.2.31 (47.0 MB) 18-12-2024

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

Visualize o Histórico de Revisões

Perguntas Frequentes Relacionadas

Number of FAQs related to AP200: 53

Expandir todosRecolher todos

  1. The AP200 uses ¼ in. tube fittings. Tubing with a 6 mm outer diameter (OD) will not fit, unless a 6 mm to ¼ in. reducer is used on each end of each tube.

  2. No. The AP200 requires flow from at least four intake assemblies for smooth operation of the pump.
  3. No. Because the AP200 has only eight inlets for air samples, it can only operate with a maximum of eight intake assemblies.
  4. A dewpoint generator is used as an H2O standard. Dewpoint generators are laboratory instruments and are not suitable for long-term deployment in the field.

  5. Possibly. For example, to measure advection because of a drainage flow on sloping terrain, an AP200 system could be deployed with two towers, upstream and downstream along the slope, with four intakes on each tower.

  6. The intake tubes can be quite long—up to a few hundred meters. Contact Campbell Scientific to ask about specific requirements for an application.

  7. A non-zero value can be used to perform a zero/span on an interval that is not synchronized to midnight (for example, every three hours starting at 0100 hrs).

  8. The spacing depends on the canopy and atmospheric conditions. It is important to know where the concentration gradients are the steepest.

    For example, in a low agricultural crop canopy, it may be appropriate to use a logarithmic distribution within and near the top of the canopy, and a linear distribution above the canopy: 0.2 m, 0.4 m, 0.8 m, 1.6 m, 3.2 m (logarithmic) and 5 m, 7 m, 9 m (linear).

Estudos de Caso

China: Flux Cooperation
This case study discusses the integration of CPEC310 and AP200 systems to explore the theories......Leia mais
Australia: Ecological Research
The Warra long-term ecological research (LTER) site located in Southwestern Tasmania was founded in 1995......Leia mais