Displaying 1 - 18 of 18 articles tagged with: CR1000

A Quick Comparison of the CR1000X, CR1000, and CR6 Dataloggers

Autor: Timothy Jeppsen | Ultima atualização: 03/19/2020 | Comentários: 4

a quick comparison of the cr1000x, cr1000, and cr6 dataloggers

We recently released the CR1000X Measurement and Control Datalogger, and you may be wondering how it compares with our widely used CR1000 datalogger and our innovative CR6 datalogger. If you’re in the market for a new data logger, how do you know which one is... Leia mais

It’s Time to Embrace the Hybrid

Autor: Kevin Rhodes | Ultima atualização: 12/02/2019 | Comentários: 0

it’s time to embrace the hybrid

Sometimes, it’s hard to let go. But if we don’t let go, we don’t have empty hands ready to embrace something new—even a data logger. The CR1000 Measurement and Control Datalogger (introduced in 2004) has been incredibly successful with installations on every continent of our planet.... Leia mais

How to Monitor Your Campbell Cellular Modem Data Usage: Part 2

Autor: Nathanael Wright | Ultima atualização: 02/07/2019 | Comentários: 5

how to monitor your campbell cellular modem data usage: part 2

In this blog article, we’ll look at how to monitor your data usage using serial commands with our external CELL2XX series of cellular modules using the CR800, CR850, CR1000, and CR3000 dataloggers. (If you have a CR300, CR310, CR6, or CR1000X datalogger, you'll want to... Leia mais

New Product Support: Kipp & Zonen’s RaZON+

Autor: Matt Perry | Ultima atualização: 01/17/2018 | Comentários: 0

new product support: kipp & zonen’s razon+

During 2017, I was asked several times for a data logger program to retrieve data from Kipp & Zonen’s new RaZON+, a compact-sized dual-axis sun tracker with integrated GPS, smart pyrheliometer, and shaded smart pyranometer. The RaZON+ touts a higher accuracy approach to obtaining solar... Leia mais

Integrated Peripherals: Expansion made easy

Autor: Timothy Jeppsen | Ultima atualização: 11/29/2017 | Comentários: 0

integrated peripherals: expansion made easy

What do expansion peripherals do, and how is integrating them helpful? Expansion peripherals have two purposes: to expand the capabilities of the data logger, both in channel count and functionality, and to improve measurement quality. What if we could provide both and make it easier... Leia mais

Replacing Your CR1000 Datalogger with a CR1000X: What You Should Know

Autor: Timothy Jeppsen | Ultima atualização: 10/11/2017 | Comentários: 8

replacing your cr1000 datalogger with a cr1000x: what you should know

As soon as people learned that we were replacing the CR1000 datalogger with the CR1000X datalogger, they asked us these questions: “Can I load a program I wrote for my CR1000 into a CR1000X?” and “Will the CR1000X fit in the same space as my... Leia mais

The CR1000X: A New Generation of Data Loggers with Proven Functionality

Autor: Timothy Jeppsen | Ultima atualização: 08/02/2017 | Comentários: 3

the cr1000x: a new generation of data loggers with proven functionality

It should come as no surprise that the CR1000 datalogger (introduced in 2004) has been an incredibly successful data logger. With nearly 100,000 deployed, this data logger has been installed on every continent on the earth. Using the design success of the CR1000, Campbell Scientific... Leia mais

Available Security Measures for Internet-Connected Data Loggers

Autor: Dana Worley | Ultima atualização: 12/07/2016 | Comentários: 2

available security measures for internet-connected data loggers

The Internet of Things offers a lot of advantages in today’s culture. There are consumer devices that let you monitor and control mood lighting and music in your home, keep track of last week’s leftover dinner in your refrigerator, and help you brew a cup... Leia mais

How to Access Live Measurement Data Using Modbus

Autor: Paul Smart | Ultima atualização: 04/07/2016 | Comentários: 24

how to access live measurement data using modbus

Did you know that you can turn your Campbell Scientific data logger into a Modbus TCP/IP server? Do you know why that’s a good idea? Campbell Scientific data loggers are commonly used as Modbus server devices. This means that the data logger is configured to... Leia mais

10+ Reasons to Be Excited about the New CR300 Datalogger

Autor: Robin Deissinger | Ultima atualização: 03/16/2016 | Comentários: 3

10+ reasons to be excited about the new cr300 datalogger

In this short interview, Kevin Rhodes, the product manager for the new CR300, tells us how this new data logger will be helpful to Campbell Scientific customers and why he thinks the CR300 is a great value. Kevin is the Director of Product Management at... Leia mais

6 Steps to Easily Parse Data from a Trusted Source

Autor: Gary Roberts | Ultima atualização: 03/02/2016 | Comentários: 1

6 steps to easily parse data from a trusted source

Would it be helpful to include data from a reputable source with your own data? If you have permission to use another source’s data for free or by agreement, how can you easily extract the specific data you want to use without doing a lot... Leia mais

Using Internet Data to Promote Outdoor Safety

Autor: Barbra Utley | Ultima atualização: 11/04/2015 | Comentários: 0

using internet data to promote outdoor safety

When it comes to weather conditions, looks can be deceiving. An area that appears to be experiencing mild weather may soon experience conditions that are dangerous to human life. How can you prepare for rapidly changing weather conditions and ensure the safety of those in... Leia mais

Meet Our 2015 Photo Contest Winners

Autor: Robin Deissinger | Ultima atualização: 10/28/2015 | Comentários: 4

meet our 2015 photo contest winners

We asked our integrators, those folks who sell and install our products, to send us their best photos of Campbell Scientific equipment operating in the field. From all of their submissions, we selected a photo from Western Weather Group as the first-place winner. Runners-up photo... Leia mais

4 New Ways to Use Array Notation: Copying or Transposing

Autor: Janet Albers | Ultima atualização: 07/21/2015 | Comentários: 0

4 new ways to use array notation: copying or transposing

Copying or transposing has become easier with OS 28 (CR6 OS 1). This new operating system enables you to copy portions of an array to a new location, such as when transposing rows and columns. In this example we start with A(3,2) (3 rows, 2 columns) initialized as... Leia mais

4 New Ways to Use Array Notation: Complex Scaling

Autor: Janet Albers | Ultima atualização: 07/01/2015 | Comentários: 0

4 new ways to use array notation: complex scaling

You can perform more complex scaling in an array without needing a For/Next loop. To take advantage of this feature, use OS 28 (CR6 OS 01) or later.   In this example program, a unique set of multipliers and offsets is applied to the column of an... Leia mais

4 New Ways to Use Array Notation: Initializing Multi-Dimensional Arrays

Autor: Janet Albers | Ultima atualização: 06/10/2015 | Comentários: 0

4 new ways to use array notation: initializing multi-dimensional arrays

Initializing variables within an array is more flexible than ever with OS 28 (CR6 OS 1). You can think of a single dimensioned array as numbers in a column. Two dimensions, in comparison, puts numbers in rows and columns. The third dimension is a page. For example:... Leia mais

6 Common Communication Problems Involving Serial Connections

Autor: Jacob Davis | Ultima atualização: 05/29/2015 | Comentários: 9

6 common communication problems involving serial connections

Your data logger may record great data, but if you can't retrieve it, the data isn’t going to do you much good. To ensure your successful data retrieval, it’s essential that you can troubleshoot possible problems that may arise with PC-to-data-logger communication over a serial... Leia mais

4 New Ways to Use Array Notation: Simple Scaling

Autor: Janet Albers | Ultima atualização: 05/29/2015 | Comentários: 0

4 new ways to use array notation: simple scaling

The newest operating system released by Campbell Scientific for its data loggers is OS 28 for the CR800, CR1000, and CR3000. (The comparable operating system version for the CR6 datalogger is OS 01.) This powerful data logger OS has been enhanced so that you can... Leia mais