Turbidity Sensors / ClariVue 10
ClariVue 10 ISO 7027-Compliant, Side-Scatter Turbidity Sensor
Side-Scatter Measurements with ISO 7027 Compliance
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The ClariVue™10 is an ISO 7027 compliant, submersible, side-scatter turbidity sensor. It outputs an SDI-12, digitally processed signal that all modern Campbell Scientific data loggers can measure. The side-scatter turbidity measurement can be used as a surrogate for suspended sediment concentration in aquatic ecosystems.

Leia mais

Benefícios e Características

  • Measures suspended solids and turbidity for up to 4000 FNUs
  • Provides a compact, low-power probe that is field proven
  • Compatible with modern Campbell Scientific data loggers
  • Accurate and rugged

imagens


3D / CAD Files:

Descrição Técnica

The ClariVue 10 is an ISO 7027-compliant, side-scatter turbidity sensor. It returns data via SDI-12 to a data logger. Turbidity is a common surrogate measurement for suspended sediment concentration in aquatic systems. The ClariVue 10 is designed to operate in fresh and saline environments. It will require regular maintenance to keep the optical window clean in high bio-fouling environments. The face of the sensor is made from copper to slow biological growth over the optical windows.

Especificações

Standards Meets ISO 7027-1:2016 (side scatter) standard for turbidity measurements.
Compliance SDI-12 v1.4 compliant
Operating Temperature Range -2° to +40°C
Measurement Range 0 to 4000 FNU
Resolution 0.2 FNU
Accuracy ±2% or 0.5 FNU (whichever is greater)
Power Requirements 9.6 to 18 Vdc
Measurement Time 9 s (with an M! instruction)
Housing Material Delrin® plastic
Head Material Marine-grade bronze
Optics Sapphire lens
Connector Descriptions Marine-grade bronze, gold-plated pins
Connector Description Bronze 3-pin wet-mate
Cable Type 3-conductor, polyurethane jacket with water block
Optical Assembly Sealed with double O-rings
Temperature Accuracy ±0.2°C
Maximum Submersion Depth 30.48 m (100 ft) for the plastic
Sensor Diameter 30.1 mm (1.185 in.)
Sensor Length 166 mm (6.54 in.)
Sensor Weight 158.76 g (0.35 lb)

Power Consumption

Quiescent < 300 µA
Measurement < 35 mA

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
CR1000X
CR300
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Downloads

ClariVue SDI-12 Program Example (1 KB) 11-08-2021

This example CR1000X program uses the M1! SDI-12 command to retrieve 100 burst measurements from a ClariVue 10 or ClariVue 20. The sensor makes 100 measurements to calculate turbidity statistics (median, mean, standard deviation, minimum, maximum) and mean temperature.

Perguntas Frequentes Relacionadas

Number of FAQs related to ClariVue 10: 2

  1. The most significant difference between backscatter and side-scatter measurements is the sample volume. A backscatter sensor has a much larger sample volume that helps measure higher turbidity values. The smaller sample volume of side-scatter sensors works better at lower turbidities.

  2. It used to be that NTUs were the unit for all turbidity sensors. In 2007, an ASTM committee formed and established different units for each category of turbidity sensor technology, and there are many. Backscatter sensors such as the OBS-3+ and the OBS501 have units of FBU (Formazin Backscatter Units), whereas ISO 7027 side-scatter sensors have units of FNU (Formazin Nephelometric Units). The side-scatter OBS501 and the ClariVue™ sensors are part of this category. While sensors of different technical designs can be calibrated and measure Formazin the same, they will not make the same measurement in natural waters where size, shape, color, reflectivity, etc., of the particles vary. The ClariVue™ sensor measurements will not match the OBS-3+ measurements in natural waters.