CURS100 100-Ohm Current Terminal Input Module
Expands Capabilities
Allows data logger to measure additional types of sensors
clima estudos de caso água estudos de caso energia estudos de caso gas flux and turbulence estudos de caso infraestrutura estudos de caso terra estudos de caso

Visão Geral

The CURS100 enables your Campbell Scientific data logger to measure a sensor or output device that outputs a current signal (for example, 4 to 20 mA). It converts the current signal to a voltage signal.

Leia mais

Benefícios e Características

  • Easy to install or remove
  • Connects directly into data logger input terminals
  • Low power consumption

imagens


3D / CAD Files:

Descrição Técnica

The CURS100 uses a 100 Ω resistor for the current shunt that allows currents up to 25 mA to be read on a ±2500 mV range (CR10X, CR510) and currents up to 50 mA to be read on a ±5000 mV range.

Schematic for CURS100

CURS100-to-Sensor Hookup

Especificações

Used With Sensors that output a current signal (4 to 20 mA)
Resistance 100 Ω (shunt—bulk metal foil)
Tolerance ±0.01% (@ 25°C)
Power Rating 0.25 W
Maximum Temperature Coefficient ±0.8 ppm/°C
Dimensions 1.5 x 1.5 x 2.7 cm (0.6 x 0.6 x 1.0 in.) for body with prongs
Weight 6 g (0.2 oz)

Compatibilidade

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired) Compatible CR9000 modules are the CR9050 and the CR9052; the CR9051 is partially compatible.
CR9000X (retired) Compatible CR9000X modules are the CR9050 and the CR9052; the CR9051 is partially compatible.

Additional Compatibility Information

Multiplexers

Our multiplexers are compatible with the CURS100.

Data Logger Considerations

Current CR10X Wiring Panels can accommodate both the CURS100 and the cover associated with the CR10XTCR (reference thermistor for thermocouple measurements). Specifically, the physical configuration of the thermocouple cover, the data logger input terminals, and the terminal input modules allow sufficient room for the cover to be used with the CURS100 attached. In contrast, older CR10TCR covers are not deep enough.

Note: The CR6 (serial number >7501), CR1000X, CR350, CR300, and CR310 data loggers can do current measurements without the CURS100. 

Programming

The CURS100 output is measured with VoltDiff Instruction in CRBasic and with Instruction 2 (Differential Voltage) in Edlog. The CURS100 consumes one differential analog input; an adjacent analog ground channel accepts the analog "ground prong" of the CURS100. Not all data logger terminal strips have this sequence on all channels, so please check your data logger's wiring panel to confirm channel assignments, especially if you plan to use multiple terminal input modules.

Perguntas Frequentes Relacionadas

Number of FAQs related to CURS100: 1

  1. Yes. A CURS100 is used to convert a current signal (for example, 4 to 20 mA) output by a sensor to a voltage that can be measured by the CR1000. The precision 100 ohm resistor used for the current shunt allows currents up to 50 mA to be read on a ±5000 mV range.

Estudos de Caso

New Mexico: Cavern Collapse Alarm
RESPEC, a water-resources consulting and services firm, is currently under contract to operate and maintain......Leia mais
Utah: Water-Supply SCADA System
In 2010, Trenton and Amalga, two northern Utah towns separated by only a few miles,......Leia mais

Artigos e Comunicados de Imprensa

listado em

Other Accessory for the following products: