ALERT205 OS / Web Interface 2.00
Atualizada: 24-01-2025

  1. (major) Updated CRBasic program to use AL200 ALERT2 API v2.0 API commands.
  2. (major) Fixed broken MSR4 reporting.
  3. (minor) Updated UI to match new Campbell Scientific, Inc. branding.
  4. (minor) Added support for the AL205R IND device.
  5. (minor) Added Center Transmission and TDMA Slot Padding to AL200 settings.
  6. (minor) Fixed App Test Flag. It now reports test transmissions correctly with the AL200's test button is pushed or when the Trigger button is pushed in the user Interface.
  7. (minor) Added if Trigger Test TX button back to the dashboard (hidden during AL200 OSv6 development).
  8. (minor) Units conversion handling was updated for the following sensors. Please review your units selection if your system is reading from any of the following: * WaterLog - Amazon Bubbler * WaterLog - H-350XL Bubbler * WaterLog - H-3611 Radar Water Level Sensor * CS475, CS475A Radar Water Level Sensor * R.M. Young - 86000-SDI Ultrasonic Anemometer.
  9. (minor) Fixed minimum Destination Address that was set incorrectly to allow a bad alert address of 0. Now set to a minimum address of 1.
  10. (minor) Added IND device firmware information to the Dashboard to aid with troubleshooting [AL2XX Status]. AL205R does not support API polling for this information, so we add, by hand, the details when this device is used.
  11. (minor) Fixed Generic Float Switch to use the EX2 port instead of the C2 port to conserve power and meet sensor power requirements.
  12. (minor) Fixed Serial port wait times to meet the CR300's serial port specifications.
  13. (minor) Fixed an issue with the GPS when the CR300 does not get a response from the IND device.
  14. (minor) Added better validation and reporting of responses from IND device for time and GPS.
  15. (minor) Updated the wiring diagram and generated CRBasic program for the Water Level (Generic Float Switch).
  16. (minor) Check AL200 settings on occasion just in case the AL200 loses power and goes back to default settings. We no longer write settings to the AL200 to keep from wearing out its memory.
  17. (minor) Ensure we have good time from the GPS, if the change is greater than 24 hours it is ignored (unless on initial startup). Sometimes the GPS (older modules) in the AL200 gets bad time data.
  18. (minor) Added a note to some bubblers warning users to connect the 12V of the sensor to a battery instead of to the listed terminal in the GUI. This was done in cases where the bubbler pulls more amperage than the ALERT205 device could support (current limits).
  19. (minor) Adjusted defaults to be as specified in the ALERT2 IND Standard v2.1 (September 2024) except Carrier Only Time and Hop Limit.
  20. (minor) Carrier only time now defaults to 5 milliseconds even though the ALERT2 standard recommends setting this to 0. There is a bug in the AL200 firmware V6.0 the prevents the use of 0 milliseconds. 1 millisecond is the lowest setting that should be used with a AL200 with firmware v6.0.
  21. (minor) Added RangeVUE15 and RangeVUE30 SDI-12 water level sensors.
  22. (minor) Fixed grammar in several help text messages.
  23. (minor) Fixed MSR4 reports that were sending data in m/s instead of km/hr.
  24. (minor) Fixes an issue with MSR reports where an air temperature was always required for a MSR3 or MSR4 report.
  25. (minor) Adjusted the multiplier for the 05103-L sensor to be 0.2192 so it will be mph instead of m/s.
  26. (minor) Fixed wiring color for Water Level (H-305XL) sensor.
  27. (minor) Fixed an issue with (05103-L) Wind Speed and Wind Direction values that are sent via ALERT2. We were sending possibly old values instead of the latest recorded values.